How to heat the wall-mounted boiler and floor heating? Analysis of hot topics on the Internet in the past 10 days
As temperatures plummet in winter, the use of wall-mounted boilers and floor heating has become a hot topic on the Internet recently. How to heat efficiently and save energy consumption are the issues that users are most concerned about. This article will combine hotspot data from the entire network in the past 10 days to provide you with structured solutions from principles, operating techniques to common misunderstandings.
1. Hot search data related to floor heating in the past 10 days across the entire network

| Ranking | Hot search keywords | Search volume (10,000) | main focus |
|---|---|---|---|
| 1 | Wall-hung boiler water temperature settings | 58.7 | optimal temperature range |
| 2 | Reasons why the floor heating is not hot | 42.3 | Blocked pipes/insufficient pressure |
| 3 | Energy and Gas Saving Methods | 36.9 | night temperature regulation |
| 4 | Wall mounted boiler fault code | 28.5 | E1/E9 error handling |
| 5 | Floor heating heating rate | 19.2 | First startup time |
2. Five core skills for efficient heating
1. Scientifically set water temperature
According to actual measured data by engineers: it is recommended that the inlet water temperature for floor heating be set between 45-55°C, and gas consumption increases by 8% for every 5°C increase. For details, please refer to the following temperature comparison table:
| outdoor temperature | Recommended water temperature | Estimated daily gas consumption |
|---|---|---|
| -10℃ or less | 50-55℃ | 10-12m³ |
| -5~0℃ | 45-50℃ | 8-10m³ |
| Above 0℃ | 40-45℃ | 6-8m³ |
2. System pressure maintenance
The pressure gauge should be kept within the range of 1.5-2bar. Lower than 1bar will cause poor circulation. Recent hot search cases show:73%The problem of "the floor heating is not hot" is caused by insufficient pressure.
3. Time-period temperature strategy
Adopt "5+2" mode: maintain 18℃ during the day on weekdays, adjust to 16℃ at night; 20℃ all day on weekends. Actual measurement can save15-20%Gas bill.
3. Solutions to recent high-frequency problems
Question 1: Some rooms are not hot?
According to the maintenance big data, the possible reasons are:
| phenomenon | Proportion | Solution |
|---|---|---|
| Single pipe blockage | 62% | Manifold exhaust cleaning |
| Thermostatic valve failure | 23% | Replace solenoid valve |
| Ground coverage is too thick | 15% | Remove carpet/furniture |
Question 2: Does the wall-hung boiler start and stop frequently?
Mainly due to: ① The minimum power is too high ② The heating area is too small. It is recommended to adjust the combustion power or install a hot water storage tank.
4. Special reminder from professional engineers
① Please wait patiently when starting for the first time4-6 hoursHeating (concrete layer heat storage)
②Check every monthfilterAnd discharge sewage once
③Professional required every 2 yearsDescaling and maintenance(In areas with hard water, once a year is required)
Through the above structured plan, combined with recent user practical feedback, the efficient operation of the floor heating system can be ensured. It is recommended to save the data table in this article and quickly check it when encountering problems.