How to vent geothermal heat
Geothermal systems are an important way of heating many homes in winter, but during use, the heating effect may be reduced due to the accumulation of air in the pipes. This article will detail how to vent geothermal heat, along with relevant data and advice to help you solve the problem efficiently.
1. Why do you need to vent geothermal heat?

The air in the geothermal pipes will hinder the normal circulation of hot water, causing insufficient heating in some areas. Here are statistics on frequently asked questions:
| Question type | frequency of occurrence | Scope of influence |
|---|---|---|
| duct noise | 35% | local area |
| Uneven heating | 50% | multiple rooms |
| System efficiency decreases | 15% | whole system |
2. Preparation work before deflation
Before you start deflating, you need to prepare the following tools and materials:
| Tools/Materials | Purpose |
|---|---|
| deflate key | For unscrewing the air release valve |
| towel or container | catch drained water |
| gloves | Prevent burns |
3. Detailed explanation of deflation steps
The following are the specific deflation steps, please operate in order:
1.Shut down geothermal system: Make sure the system is turned off to avoid hot water splashing.
2.positioning bleed valve: Usually located on top of the radiator or manifold and shaped like a small screw or valve.
3.Unscrew the air release valve: Use the bleed key to turn the valve counterclockwise until you hear a "hissing" exhaust sound.
4.Wait for exhaust to complete: When the exhaust sound stops and water flows out, it means that the air has been exhausted, close the valve immediately.
5.Check system pressure: After deflating, check the pressure gauge to ensure that the pressure is within the normal range (usually 1-2bar).
| steps | Things to note |
|---|---|
| Shut down the system | Avoid hot water splashing |
| Unscrew the air release valve | Be gentle to avoid damaging the valve |
| Check pressure | The pressure is too low and needs to be replenished with water. |
4. Common problems and solutions
During the deflation process, you may encounter the following problems:
| question | Solution |
|---|---|
| Valve cannot be unscrewed | Spray a small amount of lubricant and wait before trying again |
| Still not hot after exhaust | Check for clogged pipes or system pressure |
| water leakage | Close the valve immediately and contact a professional |
5. Maintenance suggestions after deflation
To keep your geothermal system operating efficiently, the following maintenance is recommended on a regular basis:
1.Bleed air once a year before heating: Make sure there is no air accumulation in the pipe.
2.Check system pressure: Check the pressure gauge once a month and replenish water in time.
3.Clean filter: Clean the filter once a quarter to prevent clogging.
Through the above steps, you can easily solve the air problem of your geothermal system and ensure the heating effect in winter. If the problem is complex or cannot be solved by yourself, it is recommended to contact professional maintenance personnel.